Residential:
RAS Super Daiseikai High-Wall Units, single or multi-split
- New elegant and compact design
- DC hybrid inverter with twin rotary compressors
- Superior indoor air quality
- Single or multi-split system
- Advanced and extensive air purification
- All units rated A for energy efficiency
- Quiet operation for enhanced user comfort
- Designed for use with refrigerant R410A
- Ag + Plasma Air Purifier
| Indoor Unit | RAS-10SKVP-E | RAS-13SKVP-E | RAS-16SKVP-E | |
| Outdoor Unit | RAS-B10SAVP-E | RAS-B13SAVP-E | RAS-B16SAVP-E |
| Cooling Capacity | kW | 2.5 (0.5 to 3.5) | 3.5 (0.6 to 4.5) | 4.5 (0.8 to 5.0) |
| Heating Capacity | kW | 3.2 (0.6 to 6.1) | 3.5 (0.6 to 6.9) | 4.5 (0.8 to 8.0) |
| Power Input, cooling / heating | kW | 0.49 / 0.63 | 0.85 / 0.95 | 1.35 / 1.49 |
| EER, Cooling / COP heating | W/W | 5.10 / 5.08 | 4.12 / 4.42 | 3.33 / 3.69 |
| Annual Power Consumption, cooling | kWh | 245 | 425 | 675 |
| Energy Label, cooling / heating | A/A | A/A | A/A |
| UK Conditions - Cooling Capacity | kW | 3.30 | 4.07 | 4.50 |
| UK Conditions - Sensible Cooling Capacity | kW | 2.48 | 3.05 | 3.38 |
| UK Conditions - Heating Capacity | kW | 4.62 | 4.91 | 5.80 |
| Indoor Unit | RAS-B10SKVP-E | RAS-B13SKVP-E | RASB-16SKVP-E |
| Air Flow , Cooling (High/Low) | l/s | 152/77 | 153/77 | 168/188 |
| Air Flow , Cooling (High/Low) | m3/h | 546/276 | 564/276 | 606/318 |
| Air Flow , Heating (High/Low) | l/s | 170/78 | 177/53 | 188/195 |
| Air Flow , Heating (High/Low) | m3/h | 612/1282 | 636/300 | 678/1342 |
| Sound Pressure Level (LowHigh) | dB(A) | 42/27 - 43/27 | 43/27 - 44/27 | 45/29 - 45/29 |
| Sound Power Level (Low/High | dB(A) | 57/42 - 58/42 | 58/42 - 59/42 | 60/44 - 60/45 |
| Dimensions, Height x Width x Depth | mm | 250 x 790 x 208 | 250 x 790 x 208 | 250 x 790 x 208 |
| Weight | kg | 9 | 9 | 9 |
| Outdoor Unit | RAS-10SAVP-E | RAS-13SAVP-E | RAS-13SAVP-E |
| Air flow | l/s (m3/h | 597 (2149) | 669 (2408) | 669 (2408) |
| Sound Pressure Level, cooling/heating | dB (A) | 46/47 | 48/50 | 49/50 |
| Sound Power Level, cooling/heating | dB (A) | 59/60 | 61/63 | 62/63 |
| Dimensions, Height x Width x Depth | mm | 550 x 780 x 290 | 550 x 780 x 290 | 550 x 780 x 290 |
| Weight | kg | 38 | 38 | 38 |
| Operating Range, cooling | °C | -10 to 46 | -10 to 46 | -10 to 46 |
| Operating Range, heating | °C | -15 to 24 | -15 to 24 | -15 to 24 |
| Pipe Connections, Gas - Liquid | in | 3/8 - 1/4 | 3/8 - 1/4 | 1/2 - 1/4 |
| Pipe Length, Maximum/minimum | m | 25/2 | 25/2 | 25/2 |
| Pipe Length, Pre Charged | m | 15 | 15 | 15 |
| Additional R410A Charge | g/m | 20 | 20 | 20 |
| Maximum Height Difference | m | 10 | 10 | 10 |
| Max. Operating Current (cooling 240 V) | A | 2.49 | 3.9 | 5.9 |
| Suggested Fuse Size | A | 6 | 6 | 10 |
| Power Supply | V-ph-Hz | 220/240-1-50 | 220/240-1-50 | 220/240-1-50 |
| Supply To | Outdoor Unit | Outdoor Unit | Outdoor Unit | |
| Interconnecting cables | 3+E | 3+E | 3+E |
| Retail Price | ||||
| Indoor Unit | £ | 368.00 | 368.00 | 380.00 |
| Outdoor Unit | £ | 670.00 | 830.00 | 1,100.00 |
| System Price | £ | 1,038.00 | 1,198.00 | 1,480.00 |
| Indoor unit | RAS-B10SKVP-E |
RAS-B13SKVP-E |
RAS-B16SKVP-E |
||||||||||
| Cooling capacity | kW | 14 |
18 |
26 |
27 |
14 |
18 |
26 |
27 |
18 |
26 |
27 |
|
| Remote control (included) | Infra-red |
Infra-red |
Infra-red |
||||||||||
| Cooling capacity | kW | 2.5 |
2.7 |
2.7 |
2.7 |
3.5 |
3.7 |
3.7 |
3.7 |
4.5 |
4.5 |
4.5 |
| Heating capacity | kW | 3.2 |
4.0 |
4.0 |
4.2 |
4.2 |
5.0 |
5.0 |
5.0 |
5.5 |
5.5 |
5.5 |
| Power input, cooling | kW | 0.57 |
0.60 |
0.75 |
0.75 |
1.10 |
1.10 |
1.20 |
1.20 |
1.50 |
1.65 |
1.65 |
| Power input, heating | kW | 0.85 |
1.02 |
1.50 |
1.50 |
1.25 |
1.80 |
2.05 |
2.05 |
1.90 |
2.50 |
2.50 |
| EER, cooling | W/W | 4.39 |
4.50 |
3.60 |
3.60 |
3.18 |
3.36 |
3.08 |
3.08 |
3.00 |
2.73 |
2.73 |
| Amual power consumption | kW/h | 285 |
300 |
375 |
375 |
550 |
550 |
600 |
600 |
750 |
825 |
825 |
| Energy label, cooling | A |
A |
A |
A |
D |
C |
D |
D |
D |
E |
E |
| UK Conditions | ||||||||||||
| Cooling capacity | kW | 2.60 |
3.50 |
4.32 |
||||||||
| kW | 2.16 |
2.96 |
3.60 |
|||||||||
| kW | 3.70 |
4.60 |
5.05 |
|||||||||
| Indoor unit |
RAS-B10SKVP-E |
RAS-B13SKVP-E |
RAS-B16SKVP-E |
|||||||||
| Air flow, cooling (h/m/l) | l/s |
157/106/81 |
163/109/81 |
181/120/91 |
||||||||
| Air flow, cooling (h/m/l) | m³/h | 562/381/292
|
588/394/292
|
653/432/328
|
||||||||
| Air flow, heating (h/m/l) | l/s |
176/136/81 |
182/142/81 |
189/161/91 |
||||||||
| Air flow, heating (h/m/l) | m³/h |
632/490/292 |
654/511/292
|
681/580/328
|
||||||||
| Sound pressure level | db(A) |
42/25 - 43/25 |
43/26 - 44/26 |
45/28 - 45/28 |
||||||||
| Sound power level | db(A) |
55/38 - 56/38 |
56/39 - 57/39 |
58/41 - 58/41 |
||||||||
| Dimensions, H x W x D | mm | 250 x 790 x 215
|
250 x 790 x 215 |
250 x 790 x 215 |
||||||||
| Weight | kg |
9 |
9 |
9 |
||||||||
| Retail price, indoor unit |
£350.00 |
£335.00 |
£360.00 |
|||||||||
| Outdoor unit | RAS-M14GAV-E |
RAS-M18GAV-E |
RAS-3M26GAV-E |
RAS-4M27GAV-E |
| Number of indoor units | 2 - room multisplit |
2 - room multisplit |
3 - room multisplit |
4 - room multisplit |
| EER/COP (cooling/heating) | W/W | 3.70 / 4.35 |
3.25 / 3.62 |
3.33 / 3.53 |
3.20 / 4.00 |
| Air flow | l/s (m³/h) | 550 (1820) |
583 (2100) |
833 (3000) |
833 (3000) |
| Sound pressure level, cooling / heating | db(A) | 48 / 46 |
50 / 48 |
48 / 48 |
48 / 48 |
| Sound power level, cooling / heating | db(A) | 61 / 59 |
63 / 61 |
61 / 61 |
61 / 61 |
| Dimensions H x W x D | mm | 550 x 780 x 290 |
550 x 780 x 290 |
795 x 900 x 320 |
795 x 900 x 320 |
| Weight | kg | 36 |
40 |
64 |
65 |
| Operating range. cooling / heating | °C | 5 to 43 / -15 to
24 |
5 to 43 / -15 to
24 |
10 to 43 / -15
to 21 |
10 to 43 / -15
to 21 |
| Pipe connections gas - liquid | in | 3/8 - 1/4 |
3/8 - 1/4 |
3/8 - 1/4 |
1/2 - 1/4 |
| Pipe length, maximum ( unit / total) | m | 20 / 30 |
20 / 30 |
20 / 50 |
20 / 70 |
| Pipe length, pre-charged | m | 30 |
30 |
50 |
70 |
| Maximum height difference | m | 10 |
10 |
15 |
15 |
| Maximum operating current, cooling | A | 6.9 |
7.2 |
10.8 |
10.6 |
| Suggested fuse size | A | 10 |
10 |
16 |
16 |
| Power supply | V - ph - hZ | 220/240 - 1 - 50
|
220/240 - 1 - 50
|
220/240 - 1 - 50
|
220/240 - 1 - 50
|
| Supply to | Outdoor unit |
Outdoor unit |
Outdoor unit |
Outdoor unit |
|
| Interconnecting cable | 3 + E |
3 + E |
3 + E |
3 + E |
| Retail price, Outdoor unit | £ | 912.00 |
1,012.00 |
1,660.00 |
2,055.00 |